  1 power entry modules with line filter kfc www.schurter.com /pg06 emc products iec appliance inlet c14 with filter, fuseholder 1- or 2-pole (5x20 mm or 6.3x32 mm), optional voltage se - lector (step switch) with voltage selector without voltage selector standard- or medical-filter c14 70 c description - panel mount : screw-on mounting from front side - 4 functions : appliance inlet protection class i , fuseholder with interchangeable fuse drawer for fuse-links 5x20 mm or 6.3x32 mm , with or without voltage selector (step switch) , line filter in standard and medical ver - sion - quick connect terminals 4.8 x 0.8 mm unique selling proposition - multifunctional power entry module - suitable for various fuses - highly resistant since fully potted - v-lock cord retaining approvals - vde certificate number: 40004665 (fko, fkp, fkq, fkr) - ul file number: e72928 (fko, fkp, fkq, fkr) characteristics - all single elements are already wired - the fuse drawer "fingergrip" can be removed by hand - suitable for use in equipment according to iec/ul 60950 suitable for use in medical equipment according to iec/ul 60601-1 other versions on request - variant with notch for v-lock mating cordsets references alternative: version without line filter kec alternative: standard version weblinks pdf-datasheet, html-datasheet, general product information, rohs, china-rohs, reach, distributor-stock-check, accessories, detailed request for product newly available variants corresponding to v-lock mating cordset. the connector is equipped with a notch intended for use with the latching cordset. the cord latching system prevents against accidental removal of the cordset. technical data ratings iec 1 - 10 a @ ta 40 c / 250 vac; 50 hz ratings ul/csa 1 - 10 a @ ta 40 c / 125 vac; 60 hz leakage current standard < 0.5 ma (250 v / 60 hz) medical < 5 a (250 v / 60 hz) dielectric strength > 1.7 kvdc between l-n > 2.7 kvdc between l/n-pe test voltage (2 sec) allowable operation temp. -25 c to 85 c climatic category 25/085/21 acc. to iec 60068-1 ip-protection from front side ip 40 acc. to iec 60529 protection class suitable for appliances with protection class i acc. to iec 61140 terminal quick connect terminals 4.8 x 0.8 mm panel thickness s screw: max 8 mm mounting screw torque max 0.5 nm material: housing thermoplastic, black, ul 94v-0 appliance inlet/-outlet c14 acc. to iec 60320-1, ul 498, csa c22.2 no. 42 (for cold conditions) pin-temperature 70 c, 10 a, protection class i fuseholder 1 or 2 pole, shocksafe category pc2 acc. to iec 60127-6, for fuse-links 5 x 20 or 6.3 x 32 mm rated power acceptance @ ta 23 c 5 x 20: 2.5 w (1 pole)/ 2 w (2-pole) per pole 6.3 x 32: 3.15 w (1 pole)/ 2.5 w (2-pole) per pole power acceptance @ ta > 23c admissible power acceptance at higher ambient temperature see derating cur - ves voltage selector optional, step, 3 pos. line filter standard and medical version, iec 60939, ul 1283, csa c22.2 no. 8 technical details mtbf > 1'700'000 h acc. to mil-hb-217 f
2 power entry modules with line filter kfc www.schurter.com /pg06 emc products dimensions 40.7 50 30 55 4.8x0.8 r 4.5 r 6 r 3.1 42.2 +0.2 - 0.1 0.15 58.3 27.3 ? 3.2 ? 6.3x90 28.6 +0.2 - 0.1 r 3 0 -0.2 50 230 m3/? 3.6 69.2 2.8 57.4 2 technical data of filter-components rated current [a] filter-type inductances l [mh] capacitance cx [nf] capacitance cy [nf] r [m? ] 1 standard version 2 x 10 68 2.2 - 2 standard version 2 x 4 68 2.2 - 4 standard version 2 x 1.5 68 2.2 - 6 standard version 2 x 0.8 68 2.2 - 10 standard version 2 x 0.3 68 2.2 - 1 medical version (m5) 2 x 10 68 - 1 2 medical version (m5) 2 x 4 68 - 1 4 medical version (m5) 2 x 1.5 68 - 1 6 medical version (m5) 2 x 0.8 68 - 1 10 medical version (m5) 2 x 0.3 68 - 1 10 standard and medical version 2 x 0.3 68 2.2 1 diagrams standard version with voltage selector cx l1 l2 cy cy 2) pe? l pe n 1) f1 f2 2 1 5 3 x) x) x) external connection to be made by the customer 1) line 2) load medical version (m5) with voltage selector cx l1 l2 2) pe? l pe n 1) f1 f2 2 1 5 3 x) x) r x) external connection to be made by the customer 1) line 2) load
3 power entry modules with line filter kfc www.schurter.com /pg06 emc products derating curves fuses 5 x 20 mm (1-pole) admissible power acceptance in watt 1.5 1.0 0.5 0.0 2.5 2.0 02 04 06 08 0 100 i = << i n i = 0.7 i n i = 1.0 i n ambient air temperature t a c fuses 5 x 20 mm (2-pole, per pole) admissible power acceptance in watt 02 04 06 08 0 100 i = << i n i = 0.7 i n i = 1.0 i n 2.0 1.5 1.0 0.5 0.0 ambient air temperature t a c fuses 6.3 x 32 mm (1-pole) admissible power acceptance in watt 02 04 06 08 01 00 1.5 1.0 0.5 0.0 2.5 3.15 2.0 i = << i n i = 0.7 i n i = 1.0 i n ambient air temperature t a c fuses 6.3 x 32 mm (2-pole, per pole) admissible power acceptance in watt 1.5 1.0 0.5 0.0 2.5 2.0 02 04 06 08 0 100 i = << i n i = 0.7 i n i = 1.0 i n ambient air temperature t a c attenuation loss - - - - 5? ? 1 a 2 a 4 a 6 a 10 a medical version (m5) 1 a 2 a 4 a 6 a 10 a
4 power entry modules with line filter kfc www.schurter.com /pg06 emc products all variants rated current [a] filter-type fuseholder voltage selector v-lock order number 1 standard version 1-pole - 4303.5011 2 standard version 1-pole - 4303.5012 4 standard version 1-pole - 4303.5013 6 standard version 1-pole - 4303.5014 10 standard version 1-pole - 4303.5015 1 standard version 1-pole 3 pos. 4303.5031 2 standard version 1-pole 3 pos. 4303.5032 4 standard version 1-pole 3 pos. 4303.5033 6 standard version 1-pole 3 pos. 4303.5034 10 standard version 1-pole 3 pos. 4303.5035 1 standard version 2-pole - 4303.5001 2 standard version 2-pole - 4303.5002 4 standard version 2-pole - 4303.5003 6 standard version 2-pole - 4303.5004 10 standard version 2-pole - 4303.5005 1 standard version 2-pole 3 pos. 4303.5021 2 standard version 2-pole 3 pos. 4303.5022 4 standard version 2-pole 3 pos. 4303.5023 6 standard version 2-pole 3 pos. 4303.5024 10 standard version 2-pole 3 pos. 4303.5025 1 medical version (m5) 2-pole 3 pos. 4303.5221 2 medical version (m5) 2-pole 3 pos. 4303.5223 4 medical version (m5) 2-pole 3 pos. 4303.5225 6 medical version (m5) 2-pole 3 pos. 4303.5227 10 medical version (m5) 2-pole 3 pos. l 4303.5209.21 10 medical version (m5) 2-pole 3 pos. 4303.5229 most popular. availability for all products can be searched real-time: http://www.schurter.com/stock-check/stock-check-schurter packaging unit 10 pcs required accessory description fusedrawer 3 fusedrawer for fuse links 5x20 mm resp. 6.3x32 mm fingergrip, 5 x 20, 2-pole, voltage selector 4303.2014.00 fingergrip, 5 x 20, 2-pole, voltage selector, 100, 120, 220, 240 4303.2014.01 fingergrip, 5 x 20, 2-pole, voltage selector, 110, 150, 220 4303.2014.02 fingergrip, 5 x 20, 2-pole, voltage selector, 110, 220 4303.2014.03 ...
5 power entry modules with line filter kfc www.schurter.com /pg06 emc products accessories assorted covers rear cover 0859.0072 cord retaining kits cord retaining strain relief flat head, a 4700.0001 mating outlets/connectors category / description appliance outlet overview complete iec appliance outlet f, screw-on mounting, front side, solder terminal 4787 iec appliance outlet f, snap-in mounting, front side, solder or quick-connect terminal 4788 iec appliance outlet f or h, screw-on mounting, front side, solder, pcb or quick-connect terminal 5091 appliance outlet further types to kfc connector overview complete 4782 mounting: power cord, 3 x 1 mm2 / 3 x 18 awg, cable, connector: iec c13 4782 4022 mounting: power supply cord, 3 x 1.5 mm2, screw clamps, connector: iec c13 4022 4785 mounting: power cord, 3 x 1 mm2 / 3 x 18 awg, cable, connector: iec c13 4785 4300-06 mounting: power cord, 3 x 1 mm2 / 3 x 18 awg, cable, connector: iec c13 4300-06 4012 mounting: power supply cord, 3 x 1.5 mm2, screw clamps, connector: iec c13 4012 connector further types to kfc ... mating outlets/connectors shuttered power cord overview complete vac13ks, overview, diverse connector iec c13, cord end: vac13ks power cord further types to kfc the specifications, descriptions and illustrations indicated in this document are based on current information. all content is subject to modifications and amendments. information furnished is believed to be accurate and reliable. however, users should independently evaluate the suitability and test each product selected for their own applications. 25.11.2016


▲Up To Search▲   

 
Price & Availability of 47000001

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X